What is Cold Bridging?
A cold bridge is when the inside and outside of the building are bridged by materials which conduct heat more easily than the materials surrounding it. Therefore, more heat is lost at these points, especially in winter.
Where does Cold Bridging Occur?
Badly Applied Insulation
A Thermal camera shows that insulation has only been applied to the middle of the wall and not the more difficult bits at the corners and around the window. Above the window is particularly poor.
In this photo the purple area has greater insulation and less heat being lost, the white and yellow the most heat lost. The orange brick work is in between as bricks provide some basic level of insulation.
Therefore, internal wall insulation needs to be applied to the whole of the inside walls, including the walls between the floor and the ceiling of the room below it.
Here heat is escaping between the floors of a building, due to a gap being left between the floors.
Another example of incomplete insulation is when a platform has been put in a loft to work from while putting in loft insulation. The platform is then removed but no insulation applied to the area where it was.
These types of cold bridging are easier to avoid and cheaper to rectify by checking the work while the insulation is being installed rather than afterwards.
Damaged Insulation
Cold bridging can occur when insulation, particularly loft insulation, is disturbed after it has been installed.
For example, an electrician working in the loft to repair or install a cable may move the insulation and fail to put it back properly, creating gaps that lead to thermal bridging.
It is important to check work as it goes a long and at the end before paying the final bill.
Between Materials
Cold bridging can occur wherever different materials meet because each has a different thermal conductivity. The material that conducts heat most easily creates a weak point that allows heat to escape.
Common examples include plinths or lintels around doors and windows, balconies or canopies that pass through the building fabric, and masonry shelves. Steel-framed buildings also present risks, as steel columns or girders can carry cold from the ground up through the structure. Older buildings may also have horizontal metal ties that conduct cold through the walls.
Other Places Where Cold Bridging Occurs…
-
Cold bridges can occur where wall thickness changes, for example when foundation walls are thicker than the walls above, or when ground-floor walls are double brick while the first-floor walls are only single brick. They can also occur at architectural features that project in or out, such as bay windows built in single brick.
-
If a thermal camera shows cold spots at regular intervals, they may be caused by:
metal wall ties, which typically cross the insulation in cavity walls where the remaining space is filled with insulating material
studs in a timber-frame construction
joists in ceilings and floors
-
Careful consideration is needed when materials with different thermal properties meet, such as at the junction between a wall and the floor or between external walls and the roof. Good design and planning can reduce cold bridging, although it is often difficult to eliminate thermal bridging completely. Specialist software can be used to calculate the likelihood of condensation forming.
As the examples above show, many types of thermal bridge can be avoided through good design and good implementation.
For more complex types of cold bridging, it is worth consulting a retrofit adviser or other retrofit professional. They will have specialist software that carries out U-value calculations and can quantify the heat loss caused by thermal bridging. They will also have the experience to suggest effective ways to address it and to improve the energy efficiency of your home without creating unintended consequences such as moisture problems. (U-values measure heat loss; they show how well or poorly a building component transmits heat from inside to outside.)
As you can see from the examples above, many types of thermal bridging can be avoided through good design and careful implementation.
For more complex forms of cold bridging, it is worth consulting a retrofit adviser or other qualified retrofit professional. They will have specialist software to carry out U-value calculations and quantify the heat loss caused by thermal bridging. They will also have the experience to suggest practical ways of addressing the problem and improving your home’s energy efficiency, while avoiding unintended consequences such as moisture problems.
If you need tailored advice on thermal bridging, energy efficiency or your home retrofit, contact us here and we can help you find the right approach for your home.